UNITECH BLOG
Welcome to the UNITECH Blog. Here you'll discover in-depth thought leadership pieces, product deep-dives, project highlights, industry trends and much, much more...
By Unitech | 19 November 2024 | 0 Comments

Overview of hospital handrails corridors requirements

In order to reduce or avoid the risk of injury to people with mobility impairments, such as the elderly, patients with foot injuries and weakened patients, pregnant women, children, etc., the anti-collision handrail has become a necessary measure for hospital corridors, and with the beautiful designing appearance, the hospital handrails have both practical and decorative functions.
Hospital handrails corridors requirements 

1. Hospital handrail height: according to the ergonomics and the actual situation of the patient, the installation height is the most reasonable at the upper edge 850-900mm.
2. Wall requirements: The installation site of the handrail requires the wall to be straight, In order to ensure the perfect effect of the overall installation, the deviation of the wall is 2m and the error shall not exceed 3mm.The wall should be solid and strong. If the wall is of hollow brick calcium carbonate structure, it will be necessary to reinforce the handrails at the fixing points. Hospital handrails can also be installed on walls with a certain curvature.
3. Raw material standard: 
1) Aluminum retainer: meets the GB/T1322-0981-221 high-precision standard. After testing, the hardness, acid resistance, alkali resistance and transverse impact strength of tempered aluminum are more than 5 times that of ordinary aluminum alloy keels.
2) Faceplate: using high-quality pure imported vinyl acrylate, high purity, strong flexibility, tough and smooth texture, can withstand more than 5 times the impact of the object. Not affected by weather, deformation, cracking, alkali resistance, dampness, mildew, durable.
3) Angle head: made of ABS raw material for injection molding, and the overall structure is very strong. One end of the elbow is connected to the aluminum alloy keel, and the other end is attached to the wall, so that the armrest and the wall have a close fit.
4) PPS support frame: PPS has strong hardness and is not fragile. It is the best material to connect the wall and the aluminum alloy keel, and it will not break when encountering a large impact.
4. Antimicrobial: The panel material needs to be tested in accordance with ASTM G21 standards. After 28 days of culture at 28°C, there is no mold growth on the surface to achieve a sterile space. The contractor must also attach a test report for inspection before construction.
5. Flame resistance: The panel must pass the CNS 6485 flame resistance test, and it can be naturally extinguished within 5 seconds after the fire source is removed. The contractor must submit a test report for inspection before construction.
6. Abrasive resistance: The panel material needs to be tested according to ASTM D4060 standard, and it shall not exceed 0.25g after the test.
7. Resistance to soiling: The panel material needs to pass the test according to ASTM D1308 standard, and it can be wiped clean with water for common weak acid or weak alkali pollution.

 
Unitech - Perfect Hospital Handrails Corridors Suppliers & Manufacturers
Unitech is the leading manufacturer for hospital handrails corridors system. We have 3 different designs handrails - flat surface, round and combination of a handrail with wall guard. All of them are manufactured strictly complying with the above 7 requirements. They are also suitable for use in a wide range of environments including healthcare, education, commercial office and transport.
B90 hospital hallway handrail - round or arc shaped design, Comfortable grip handrail available in solid colors and contemporary finishes.
B138 hospital handrail - flat surface design, which also can be bent for curved sections.
B160 hospital corridor handrail - combination of rail and wall guard, providing protection against impact from wheeled traffic whilst offering a comfortable grip to give reassuring pedestrian support and guidance.


Project Spotlight: Malaysia JEC eye hospital





Project Details:
This project asks for many special requirements, for example, the distance between the outer edge of the handrail elbow and the door cover line must be determined at 20mm; The distance between the fixed points of each support must be controlled between 280-680mm; Handrails are required to form a straight line with no height difference...etc.
Despite this, our engineers successfully designed solutions and products that meet the requirements and ultimately won the hospital's praise. In fact, besides the handrails, we also provide PVC wall guards, PVC corner guards, flexible pvc skirting, transition strips, PVC welding rods to the same hospital to complete the whole flooring accessories.

Choose a credible supplier is very important. Unitech's elegant and modern handrails will ensure the safety of all patients in the hospital and also make the hospital more artistic.

 